BLYDH - SYNTHOL HARDENER, 8010
- MSDS: BLYDH
- Manufacturer: MARTIN SENOUR AUTOMOTIVE SALES
- Product Name: SYNTHOL HARDENER, 8010
- National Stock Number: 8030-00N022638
Product Identification
Product ID:SYNTHOL HARDENER, 8010
MSDS Date:02/08/1988
FSC:8030
NIIN:00N022638
MSDS Number: BLYDH
Responsible Party
COUNTRYSIDE, IL 60525
US
Emergency Phone: 216-566-2917
Info Phone: 216-566-2902
Cage: MART3
Contractor
Telephone: 216-566-2902
Cage: 16772
Ingredients
NO INGREDIENT FOR THIS FORMULATION_INGREDIENT
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:IRRITATION OF EYES, SKIN & RESP SYS.
MAY CAUSE NERV SYS DEPRESS. EXTREME OVEREXP MAY RESULT IN UNCON &
POSS DEATH. HDCH, DIZZ, NAUS, & LOSS OF COORD ARE INDICATIONS OF
EXCESSIVE EXPOS TO VAPS/SPRAY MI STS. REDNESS & ITCHING OR BURNING
SENSATION MAY INDICATE EYE OR EXCESSIVE SKIN EXPOS.
CHRONIC:PROLONGED(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:OVEREXPOSURE TO SOLVENT INGREDIENTS
MAY CAUSE ADVERSE EFFECTS TO THE LIVER, URINARY, BLOOD FORMING, &
REPROD SYSTEMS. PERSONS SENSITIVE TO ISOCYANATES WILL EXPERIENCE
INCREASED ALLERGIC REACT ION ON REPEATED EXPOSURE. REPORTS HAVE
ASSOCIATED REPEATED AND PROLONGED OVEREXPOSURE W/PERMANENT BRAIN &
NERV SYS DMG.
Medical Cond Aggravated by Exposure:MAY CAUSE ALLERGIC RESP &/OR SKIN
REACTION IN SUSCEPTIBLE PERSONS OR SENSIT. THIS EFT MAY BE DELAYED
SEVERAL HOURS AFTER EXPOS. NO PERSON SHOULD USE THIS PROD, OR BE IN
AREA WHERE IT IS (SEE ING 17)
First Aid
First Aid:INHAL:IF ANY BRTHG PROBLEMS OCCUR DURING USE, LEAVE AREA &
GET FRESH AIR. IF PROBLEMS REMAIN OR OCCUR LATER, GET MD IMMED.
SKIN:WASH AFFECTED AREA THORO W/SOAP & WATER. REMOVE CONTAM CLTHG &
LAUNDER B EFORE REUSE. EYE:FLUSH W/LGE AMTS OF WATER FOR AT LEAST
15 MINS. GET MD. INGEST:NEVER GIVE ANYTHING BY MOUTH TO AN
UNCONSCIOUS PERSON. DO NOT INDUCE VOMIT. GIVE SEVERAL GLASSES OF
WATER . GET MD.
Fire Fighting
Flash Point Method:PMCC
Flash Point:80.0F,26.7C
Lower Limits:0.7%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. WATER SPRAY MAY BE INEFTIVE. IF WATER IS USED, FOG NOZZ ARE
PREF.WATER MAY BE USED TO COOL CLSD(SUPP DATA)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPARKS & OPEN FLAME. CLSD CNTNRS MAY EXPLODE WHEN
EXPOSED TO EXTREME HEAT. APPLIC TO HOT SURFS (SUPDAT)
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNIT. VENT AREA. ALL
PERS IN AREA SHOULD BE PROT. COVER SPILL W/ABSORBENT MATL.
DEACTIVATE SPILLED MATL W/10% AMMONIUM HYDROXIDE SOLN (HOUSEHOLD
AMMONIA). AFTER 10 MINS, COLLECT IN OPEN CNTNRS & ADD MORE
AMMONIA.(SEESUPP DATA)
Neutralizing Agent:10% AMMONIUM HYDROXIDE SOLUTION.
Handling
Handling and Storage Precautions:CONTENTS ARE FLAMM. KEEP AWAY FROM
HEAT, SPARKS, & OPEN FLAME. KEEP CNTNR CLOSED WHEN NOT IN USE.
CONSULT NFPA CODE. USE APPRVD BONDING/GROUNDING PROC
Other Precautions:USE ONLY W/ADEQ VENT.AVOID BRTHG VAP/SPRAY MIST.AVOID
CONT W/SKIN & EYES. COATING MAY CNTN MATLS CLASSIFIED AS NUISANCE
PARTICULATES, SUCH AS TITANIUM DIOXIDE OR CALCIUM CARBONATE WHICH
MAY BE PRESENT AT HAZ LEVELS ONLY DURING SANDING(ING 7
Exposure Controls
Respiratory Protection:ALL RESPS MUST BE NIOSH/MSHA APPRVD. WHERE
OVERSPRAY PRESENT, POSITIVE PRESS AIR SUPPLIED RESP (TC19C) SHOULD
BE WORN. IF UNAVAILABLE, PROPERLY FITTED ORG VAP/PARTICLULATE RESP
FOR PROT MAY BE EFTIVE. FOLLOW RESP MFRS DIRECTIONS(SEE ING 13)
Ventilation:LOC EXHST PREFERABLE. GENERAL EXHAUST ACCEPTABLE IF EXPOS
TO MATLS IS MAINTAINED BELOW APPLIC EXPOS LIMITS. (SEE ING 16)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:USE BARRIER CREAM ON EXPOSED SKIN.
Work Hygienic Practices:WASH HANDS AFTER USING.
Supplemental Safety and Health
FIRE FIGHT PROC:CNTNRS TO PREVENT PRESSURE BUILD-UP & POSSIBLE
AUTOIGNITION OR EXPLOSION WHEN EXPOSED TO EXTREME HEAT. EXPLO
HAZ:REQUIRES SPECIAL PRECS. DURING EMERG CNDTNS OVEREXP TO DECOMP
PRODS MAY CAUSE HLTH HAZ. SYMPS MAY NOT BE IMMEDAPPARENT. GET MD.
SPILL PROC:COVER LOOSELY. WASH SPILL AREA WITH SOAP & WATER.
Chemical Properties
HCC:F4
Boiling Pt:B.P. Text:255F,124C
Vapor Pres:SEE ING
Vapor Density:HVR/AIR
Spec Gravity:0.928
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:76.1
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:CONTAM W/WATER, ALCOHOLS, AMINES/OTHER
CMPDS WHICH REACT W/ISOCYANATES, MAY RESULT IN DANGEROUS PRESS IN,
& (SEE ING 18)
Hazardous Decomposition Products:BY FIRE:CO, CO*2, NO*X & POSSIBLY
HYDROGEN CYANIDE.
Disposal
Waste Disposal Methods:WASTE FROM THIS PROD MAY BE HAZ AS DEFINED UNDER
RCRA 40 CFR 261. WASTE MAY BE TESTED FOR IGNIT TO DETERMINE APPLIC
EPA HAZ WASTE NUMBERS.INCIN IN APPRVD FACILITY. DO NOT INCIN CLSD
CNTNR. DISP OF I/A /W FEDERAL, STATE & LOCAL REGS REGARDING
POLLUTION
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.